Language:English
High Voltage Differential Probes
Home > Mall > Oscilloscope Probes > High Voltage Differential Probes
  • ETA5056   High voltage differential probe
    • Bandwidth

      100MHz

    • Rise time

      ≤3.5ns

    • Accuracy

      ±2%

    • Attenuation ratio

      200X;2000X

    • Voltage range

      ±5600V DC+Peak AC

    • Common mode voltage

      ±5600V DC+ Peak AC

    • Maximum input voltage to ground

      2800V CAT I 1400V CAT II Vrms

    • Delay time

      20ns±1ns

    • Linearity

      ±1%

    • Input impedance

      Single-ended to ground 16MΩ ± 1%; Two input terminals 32MΩ ± 1%

    • Input capacitance

      Single-ended to ground <4pF ;Two input terminals <2pF

    • CMRR

      DC > 80dB ;100Hz > 60dB; 1MHZ > 50dB

    • Noise level

      200X < 300mVrms ; 2000X < 2000mVrms

    • Overload indication voltage threshold

      200X ≥ 580V; 2000X ≥ 5800V

    • Overload indicator lamp

      Red Light

    • Input Wire Length

      60mm

    • Output lead length

      90mm

    • Overall dimension

      120mmx55mmx24mm

    • Weight

      150g

    • Working temperature and humidity

      0~40°C,80% or less

    • Save temperature and humidity

      -10~40°C,80% or less

    • Power

      USB 9V/1A Adapter

    $557.00
  • ETA5215B   High voltage differential probe
    • Bandwidth

      200MHz

    • Rise time

      ≤1.75ns

    • Accuracy

      ±2%

    • Attenuation ratio

      50X;500X

    • Voltage range

      ±1500V DC+Peak AC

    • Common mode voltage

      ±1500V DC+ Peak AC

    • Maximum input voltage to ground

      600V CAT III 1000V CAT II Vrms

    • Delay time

      14ns

    • Input impedance

      Single-ended to ground 5MΩ ± 1%;
      Two input terminals 10MΩ ± 1%

    • Input capacitance

      Single-ended to ground <4pF ;Two input terminals <2pF

    • CMRR

      DC > 80dB ;100KHz > 60dB; 1MHZ > 50dB; 3.2MHz > 30dB; 50MHz > 26dB

    • Noise level

      50X < 50mVrms ; 500X < 300mVrms

    • Overload indication voltage threshold

      50X ≥ 150V; 500X ≥ 1500V

    • Bandwidth Limit (5MHZ)

      ≥-3dB @ 5MHZ

    • Overload indicator lamp

      Red Light

    • Overload alarm sound

      support; optionally off

    • Bias adjustable function

      Support

    • Terminal load requirements

      ≥100kΩ

    • Power

      USB 5V/1A Adapter

    $7,049.00